Technical data
9.1
Data sheet for ICD880/ICD890 camera
Type
ICD880-32121xx
ICD890-32001xx
ICD890-32011xx
ICD890-33001xx
ICD890-33011xx
Function
Camera
MTBF of the device
> 80,000 h
MTTR of the device
1)
< 10 min
CMOS sensor (scan)
Line camera with 8,192 pixels
Line frequency (scanning rate)
Max. 19 kHz
Max. 30 kHz
Image resolution
330 dpi with a reading
distance of 0.8 m
190 dpi with a reading
distance of 1.4 m
250 dpi with a reading distance of 2 m
170 dpi with a reading distance of 3 m
Usable aperture angle
Max. 36° up to reading
distance of 1.05 m
Max. 25° up to reading distance of 2.4 m
Cover for width of conveyor in
conveyor system
600 mm with a resolution
of 250 dpi
800 mm with a resolution
of 200 dpi
1,000 mm with a resolution of 170 dpi
600 mm with a resolution of 250 dpi
Depth of field (DOF)
550 mm with a resolution
of 200 dpi
250 mm with a resolution
of 250 dpi
1,600 mm with a resolution of 170 dpi
600 mm with a resolution of 250 dpi
Reading areas
0.75 m ... 1.4 m
1.4 m ... 3 m
1.6 m ... 3.3 m
Max. conveyor speed (objects)
2.4 m/s with a resolution of 200 lpi
3.2 m/s with a resolution of 150 lpi
3.8 m/s with a resolution
of 200 lpi
5.1 m/s with a resolution
of 150 lpi
Supported lenses (standard)
Focal length 80 mm
Focal length 135 mm
Focus
Dynamic
Image data output format
JPEG, TIFF
Ambient light immunity
2,000 lx (on 1D/2D code)
Print contrast (PCS)
≥
40%
1D code types (bar codes)
2/5 interleaved, Code 39, Code 128, EAN/UPC with add-on, Codabar, EAN 128
2D code types
Data Matrix ECC200, PDF417, MaxiCode, QR code, Aztec (optional)
Number of objects per second
Max. 10
Minimum object distance
50 mm
Number of codes per object
1D: max. 50, 2D: max. 10
Number of characters per 1D code
Max. 50 characters (max. 1,000 characters across all 1D codes per reading gate)
Number of characters per 2D code
Max. 1,556 bytes
Print ratio for 1D code
2:1 ... 3:1
Number of multi-reads (1D code)
1 ... 99
Memory card for parameters (cloning) SD card, 2 GB
Optical indicators
5 x LEDs (status indicators)
Read cycle
Via MSC800
Tab. 34: Technical specifications for the ICD880/ICD890 camera