7.2
Replacing a camera system or component
Faulty or damaged components must be dismantled and replaced with new or repaired
components.
NOTE
Risk of damage
Repair work on the camera system may only be performed by qualified and authorized
service personnel.
WARNING
Risk of injury due to falling components
A unit consisting of the illumination unit and camera weighs up to approximately 37 kg
depending on the variant.
Measures
▸
Do not perform any mounting work alone.
▸
Ask a second person to hold the camera system during the mounting process.
▸
When replacing the illumination unit or the camera, individually remove the camera
first and then the illumination unit.
▸
The components must be lifted from the bracket in accordance with ergonomic
principles.
▸
Wear safety shoes.
NOTE
Claims under the warranty rendered void
Do not open the device housing. The devices are sealed.
If the device is opened, any warranty claims against SICK AG will be void.
7.2.1.1
Replacing camera system components
Faulty or damaged components of the camera system must be dismantled and replaced
with new components or components repaired by SICK.
The camera features a microSD card on which all parameters of the device are
permanently stored. This makes replacing the component very easy.
Removing connecting cables
1. Switch off the supply voltage for the camera system.
2. Undo all cables with an external source in the terminal compartment of the camera and
disconnect them.