COMMISSIONING AND CONFIGURATION
6
77
8011325/18IM/2020-07-02|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
6.3.3
Saving the parameters permanently
All parameters which you enter in SOPAS-ET are transferred to and executed on the
connected camera system with the
Immediate Download
option. However, the data is
only saved
temporarily
in the camera system.
Saving the configuration permanently
To retain the changes after the camera system is restarted, the configuration must be
permanently saved in the camera system.
1. To do this, go to the SOPAS toolbar and click the
Permanently Save Parameters
icon.
The configuration is transferred to the camera system and saved there permanently.
2. The configuration that is saved permanently in the device is loaded whenever the
camera system is restarted.
Saving the configuration on the PC
You can also save the configured and displayed settings in a configuration file on your PC
in the format
*.spr
. The settings within this file can be loaded subsequently (if required)
and transferred to the camera system.
1. Go to the project window toolbar and click the
Save Project
button.
2. Select a directory and file name and then confirm your choice.
Printing the configuration
You can also print the current parameter set.
1. Select the
Device
Print/Print preview
command in the menu bar.
The SOPAS-ET configuration software displays a preview of all parameter values in
table form.
2. Print the parameters using the printer icon. The current settings for the project are
printed in table form on several pages.
In order to save the current parameter set as a PDF, go to the
Device
menu bar and
select the
Print/Save as PDF file
command.
TIP