4
MOUNTING
38
8011325/18IM/2020-07-02|SICK
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
Subject to change without notice
4.2.4
Placement on the conveyor system
The exact placement of the components on the mounting frame depends on project-
specific requirements and on the number of camera systems used.
Single-side reading
The following diagram visualizes single-side reading from above. The camera system and
deflector mirror are mounted above the conveyor system.
Fig. 19: Single-side reading from above: placement of the camera system above the conveyor
system
Multi-side reading
In the following diagram, three camera systems have been combined with each other for
multi-side reading.
Fig. 20: Multi-side reading: placement of several camera systems with VMS4xx/5xx on conveyor
system
For dynamic focusing, the camera needs continuous information about the distance to the
object surface. In the example of a volume measurement system mounted above the
conveyor, the distance values are determined and forwarded to the camera systems via
the controller unit.