Operating instructions
Chapter
5
ICR 84x Image Code Reader
Electrical installation
8 010 961/0000/10-05-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-7
5.5
Performing electrical installation
5.5.1
Overview of connection procedure
•
Connecting the power supply
•
Connecting the host interface
– or –
Connecting the CAN interface
•
Connecting the auxiliary interface (connecting the PC for parameterization)
•
Connecting the Ethernet interface and the PC to Ethernet for image output
(recommended)
•
Connecting the “Sensor 1“ and “Sensor 2“ switching inputs
•
Connecting the “Result 1“ and “Result 2“ switching outputs
5.5.2
Tools
•
Tool
•
Digital measuring device (current/voltage measurement)
5.5.3
Connecting the power supply
If the ICR is powered via the CDB 420 or CDM 420 Connection Module, the power supply
does not have to be wired separately.
1.
Ensure that the power supply to the CDB 420 or CDM 420 is switched off.
2.
Connect the 15-pin cable plug on the ICR to the corresponding device socket on the
CDB 420 or CDM 420 and screw it tightly. The connection cable can be extended by
2 m (6.56 ft) using the extension cable no. 6 010 075.
The data and functional interfaces of the ICR are connected to the connection module.
– or –
External power supply unit:
¾
Connect the power supply to the red wire (pin 1, +V
S
) and the black wire (pin 5, GND)
of the cable no. 6 010 137 (see also
).