2
Scope of application of the document
This document is for a standard HIPERFACE DSL
®
application. For safety applications,
please only refer to the document “HIPERFACE DSL
®
safety manual (8017596)".
2.1
Symbols used
NOTE
Notes refer to special features of the device. Please pay attention to these notes. They
often contain important information.
Tips provide additional information that facilitates using the documentation.
CAUTION
Safety notes contain information about specific or potential dangers, and misuse of the
application. This information is to prevent injury.
Read and follow the safety notes carefully.
2.2
Associated documents
Along with this manual, the following documents are relevant for the use of the HIPER‐
FACE DSL
®
interface:
Document number
Title
Status
8017596
HIPERFACE DSL
®
safety manual
2018-01-15
Table 1: Associated documents
Individual encoder types with the HIPERFACE DSL
®
interface are described with the fol‐
lowing documents:
•
Data sheet
•
Operating instructions
•
Errata document
2.3
HIPERFACE DSL
®
for Motor Feedback Systems
This document describes the use and implementation of the HIPERFACE DSL
®
data pro‐
tocol installed in motor feedback systems of servo drives.
HIPERFACE DSL
®
is a purely digital protocol that requires a minimum of connection
cables between frequency inverter and motor feedback system. The robustness of the
protocol enables the connection to the motor feedback system via the motor connec‐
tion cable.
Motor feedback systems with the HIPERFACE DSL
®
interface can be used across all per‐
formance ranges and substantially simplify the installation of an encoder system in the
drive:
•
Standardized digital interface (RS485)
•
Analog components for the encoder interface are not required
•
Standardized interface between the frequency inverter application and the proto‐
col logic
2
SCOPE OF APPLICATION OF THE DOCUMENT
6
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
8017595/ZTW6/2018-01-15 | SICK
Subject to change without notice