8.8.3
Set access level
This resource is used to set or read the encoder access level. The access level deter‐
mines which functions are accessible for the user application. The access level
required for each function is set out in the resources list (
Direct read access to Set access level returns the defining values:
Table 122: Set access level defining values
Defining value
Offset
Value
RID
104h
Resource name
0
"SETACCESS"
Data size
1
8
Read access level
2
0
Write access level
3
0
Time overrun
4
70
Data type
5
18h – structure with 8 bytes
Mandatory
yes
After switch-on or after a reset, the access level is always set to "0", i.e. to the lowest
(public) access rights.
To alter the access level, the corresponding access key must be transmitted to the DSL
encoder. The access level is retained until another level is set using this resource.
The table below sets out the access levels and the standard access keys available with
which the appropriate level can be set.
Table 123: Access levels and standard access keys
Access level
Standard access key
Usage
0
No access key necessary Publicly accessible system functions
1
31 31 31 31h
Protected system functions - "operator" level
2
32 32 32 32h
Protected system functions - "maintenance" level
3
33 33 33 33h
Protected system functions - "authorized client"
level
4
34 34 34 34h
Protected system functions - "service" level
The access level is given in the following format:
Table 124: Set access level definition
Byte
Value
Description
7/6/5/4
0000 0000 to FFFF FFFFh
Access keys for the requested
access level
3/2/1
Reserved for later use
0
00h to 04h
Requested access level
The currently set access level can be determined using a read access. This access level
is returned in byte 0 of the long message.
For this resource, access to the offset base is not meaningful as the size of the
resource data is smaller than the maximum for a "long message" transaction.
MOTOR FEEDBACK SYSTEM RESOURCES
8
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
117
Subject to change without notice