Product Description
FLPS Multibarrier · Operating Instructions · 8021769/V1-0/2018-03 · © SICK Engineering GmbH
15
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
3.3
Device versions
The FLPS Multibarrier is available in two standard device versions:
Table 1
FLPS Multibarrier device versions
3.4
Interfaces
3.4.1
Communication via Modbus TCP
The device version FLPS2-6004E-S-5 is equipped with an Ethernet interface with data pro-
tocol Modbus TCP.
3.4.2
Service access via USB
Both device versions FLPS2-60042-S-5 and FLPS2-6004E-S-55 are equipped with a mini
USB 2.0 interface.
Part number
Model name
Description
2098122
FLPS2-60042-S-5
FLPS Multi Barrier FLPS2-60042-S-5
Multi-channel power and input isolating amplifier for
intrinsically safe installation of FLOWSIC600/-XT family
devices
– DIN-rail housing NS35: 45x114.5x99mm
– 4 digital I/O (puls/status)
– 2 serial I/O (RS485)
– 1 mini USB 2.0 Service I/O
2098136
FLPS2-6004E-S-5
FLPS Multi Barrier FLPS2-6004E-S-5
Multi-channel power and input isolating amplifier for
intrinsically safe installation of FLOWSIC600/-XT family
devices
– DIN-rail housing NS35: 45x114.5x99mm
– 4 digital I/O (puls/status)
– 1 serial I/O (RS485)
– 1 Ethernet I/O
– 1 mini USB 2.0 Service I/O