Product Description
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
33
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
Table 2
Possible sources for analog output and impulse output
Table 3
Hardware variant / output configuration without integrated Electronic Volume Corrector (EVC)
Reg.
Measurement output
#7001
Flow rate at flowing conditions (a.c.)
#7002
Flow rate at base conditions (s.c.)
#7003
Speed of sound (SOS) (averaged over paths)
#7004
Velocity of gas (VOG) (averaged over paths)
#7046
Molar mass
#7047
Mass flow
Hardware variant/Output configuration
1
1
X(Y/Z):
X = Code for hardware variant and output configuration within the new internal Key Code.
Y = Code for hardware variant within the Key Code (
Z = Code for output configuration.
Analog board
Standard
1 (1/1)
2 (1/2)
3 (1/3)
4 (2/4) 5 (2/4) 6 (2/5) 7 (2/5) 9 (4/7)
0 (4/2)
Low
pressure
E (7/1)
F (7/2)
G (7/3)
H (8/4)
I (8/4)
J (8/5)
K (8/5) L (9/7)
Q (9/2)
Ou
tput
t
er
m
inal
31/32
Pulse
Pulse
Status
Analog
Analog/
HART
Analog
Analog/
HART
Analog
Pulse
33/34
RS485
RS485
RS485
RS485
RS485
RS485
RS485
RS485
RS485
51/52
Pulse
Pulse
Pulse
Pulse
Pulse
Status
Status
Pulse
Pulse
41/42
Status
Status
Status
Status
Status
Status
Status
Status
Status
81/82
Status
RS485
Status
Status
Status
Status
Status
RS485
RS485