5.7.2.2
Configuration of DataLogs
The following parameters can be configured on the Configuration tab of the DataLogs page
(
) to best suit the specific application (for more details see
and
following):
●
Type of dataset,
●
Storage cycle,
●
Storage behavior,
●
Active flow direction,
●
Accounting hour
●
Distribution of FRAM capacity.
When the meter is shipped, the DataLogs are preconfigured.
Changes to the parameters "Type of dataset", "Storage behavior" or "Direction"
will erase all entries from the DataLog which is changed.
If configuring these parameters after commissioning, first download and
export all entries according to
, to prevent loss of data.
Table 23
Standard DataLogs configuration when meter is shipped *
Configuration
parameter
Hourly log
Daily log
Diagnostics
comparison log
Type of Dataset
Diagnostic values
Volume counters
Diagnostic values
Storage cycle
1 hour
1 day
5 min
Storage behavior
Overflow
Overflow
not applicable
Active flow
direction
Forward
Forward
Bidirectional
Accounting hour
not applicable
0 (midnight)
not applicable
Max. number of
entries
Entries for approx. 38
days
Entries for approx. 2
years
20 entries
* Depending on location, the DataLogs for the specific FLOWSIC600 may be
preconfigured to fit the requirements e.g. of API, MID or PTB. These settings
may differ from the defaults described here.