3.1.2
Mounting of sensors to tunnel wall
The sensors should be positioned at the same height on opposite tunnel walls.
Mark holes for sensors on the same horizontal axis on each side of tunnel wall
Drill holes for screws for mounting bracket at 70 mm
Insert anchor (heavy duty anchors included in delivery)
Fasten sensors with hexagon screws or nuts
Sensors are marked 'A' and 'B', and must be mounted relative to air flow direction as
shown in
The sensors can be adjusted slightly in order to align them with one another as shown
in
Fig. 9
Depth
D
Drill hole Tunnel wall/roof
Heavy duty anchor
l
Mounting bracket
Mounting set
Dia.
Depth
Notes
2M8-1.4571
12
60
The anchor should be flush with the
tunnel wall/roof