12
8015675/1EEU/2021-12| SICK
OP E R A T I N G I N S T R U C T I O N S | Flow-X
Subject to change without notice
3
PRODUCT DESCRIPTION
3.5
Type plate
The Flow-X flow computer type plate contains the following information: CE code, MID
approval number, notified body, serial number, year of manufacture, operating temperature
according to MID approval and Test Certificate number.
Fig. 6: Type plate
3.6
Multi-module operation
The Flow-X/P flow computers normally have more than one Flow-X module. These modules
can be used in single or multi-module operation. In single module operation, each module
acts as an independent flow computer. In multi-module operation, all modules work
together as one flow computer, with data exchange via the Ethernet interface.
3.7
Configuration protection
3.7.1
Parameter locking switch
Each individual Flow-X module has a mechanical parameter locking switch, which prevents
the change of crucial parameters within the program.
Fig. 7:
Parameter locking switch
3.7.2
Metrological seal
All Flow-X enclosures have the option of sealing the parameter locking switch of the
individual Flow-X modules with a seal. On a Flow-X/P enclosure, one bar is used to seal all
installed Flow-X modules with one lead seal.
3.7.3
Passwords
Access to the parameters and functions of the Flow-X computer via the touchscreen or a
connected computer is password protected.
1
2
3
1 Label with MID code affixed after confirmation of
compliance with the Measuring Instruments
Directive
2 MID code, where yy is the year of conformity
3 XXXX is the number of the Notified Body under
whose responsibility conformity has been
confirmed.
Parameter locking switch