Ethernet gateways
Power-up sequence
On power-up, the following LED test sequence is performed:
MS LED Off for 6 s
MS LED Red for 0.25 s
MS LED Green for 0.25 s
MS LED Off
5.3.2
Basic configuration — Assigning an IP address
Configuration of the FX0-GMOD is performed via the Flexi Soft Designer tool.
Via Flexi Soft Designer tool
Open the Flexi Soft Designer and load the hardware configuration including the Modbus
TCP gateway.
Click on the
Gateways
button above the main window and select the FX0-GMOD or
double click the FX0-GMOD in the hardware configuration view to open the gateway
configuration dialog.
Click on
Gateway configuration
on the left hand menu. The following dialog appears:
Enter a valid
IP address
,
Subnet mask
and if required a valid IP address for a
Default
gateway
.
Click
OK
.
Click
Connect
to go online and download the configuration to the Flexi Soft system.
Fig. 36: Modbus TCP gateway
configuration dialog