Parameter
Description
Total muting time
0 = infinite, 5 s … 3,600 s, adjustable in 1 s increments
"Parameter Total muting time", page 104
Concurrency monitoring
time
0 = infinite, 10 ms … 3,000 ms, adjustable in 10 ms increments.
If the value is not 0, it must be greater than the logic execution
time.
"Parameter Concurrency monitoring time", page 104
Suppression of sensor sig‐
nal gaps
0 = infinite, 10 ms ... 1,000 ms, adjustable in 10 ms increments.
If the value is not 0, it must be greater than the logic execution
time.
see "Parameter Suppression of sensor signal gaps", page 104
Additional muting time
after the ESPE is released
0 ms, 200 ms, 500 ms, 1,000 ms
"Parameter Additional muting time after the ESPE is released",
page 105
Input C1
•
Active
•
Deactivated
Override input
•
Active
•
Deactivated
Conveyor
•
Active
•
Deactivated
Sequence/timing diagram
Figure 45: Sequence/timing diagram
7
CONFIGURATION
94
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
8024589/2020-11-10 | SICK
Subject to change without notice