3.2.7
Module overview, adjustments and facilities for connecting sensors
Module
Description
UE410-MU
•
Main unit of the Flexi Classic modular safety
controller
•
4 safe inputs and 4 safe outputs
•
Storage of the system configuration
UE410-GU
•
Central function block of the Flexi Classic
modular safety controller
•
Global emergency stop can be realized
•
4 safe inputs
•
1 safe output
•
Storage of the system configuration
UE410-XU
•
Input/output extension/subsystem
•
4 safe inputs and 4 safe outputs
•
Identical functionality as UE410-MU
UE410-8DI
•
Input extension
•
8 safe inputs
•
Information coupling to the upstream UE410-
MU, UE410-GU or UE410-XU module
UE410-2RO
2 contacts (N/O), 1 signal contact (N/C)
UE410-4RO
4 contacts (N/O), 2 signal contacts (N/C)
Flexi Classic gateways
e.g. UE410-PRO, UE410-DEV,
UE410-CAN
Status and diagnostics (information that is not
safety relevant) of a Flexi Classic on a fieldbus
(see Flexi Classic Gateways operating instructions)
Setting possibility
Can be set at the module
Comment
ENTER button
UE410-MU/UE410-GU
Saving of all Flexi Classic system
programs, settings and wiring
Program 1-9
UE410-MU/UE410-
GU/UE410-XU
Selection of the safety sensors
and of the logic elements to be
connected
Off delay
0-5 s, 0-50 s or
0-300 s
UE410-MU/UE410-XU
Delays 1 or 2 outputs on the
module
3 different variants available
(Not on UE410-xxxT0)
Switch position 0-9
UE410-8DI
Selection of the logic elements
and of the safety sensors to be
connected
Tab. 6: Module overview
Tab. 7: Overview of setting
possibilities