ASSEMBLY AND INSTALLATION
3
3.2
Assembly
Carry out all assembly work onsite. This includes:
▸
Fitting the flange with tube
▸
Fitting the MCU control unit,
▸
Fitting the optional external purge air unit.
3.2.1
Fitting the flange with tube
Fig. 17: Fitting the flanges with tube
Dimension a must be large enough so that a weatherproof cover can be fitted easily when
necessary (approx. 40 mm).
Work to be performed
▸
Measure the fitting location and mark the assembly location.
Leave enough clearance around the flange with tube to fit the sender/receiver unit and
reflector.
WARNING:
▸
Observe the relevant safety regulations as well as the safety notices during
all work:
see “Important Information”, page 7
▸
Consider the equipment weight specifications when planning the mounting
brackets.
▸
Only carry out assembly work on equipment with hazard potential (hot or
aggressive gases, higher internal duct pressure) when the equipment is at a
standstill.
▸
Take suitable protection measures against possible local hazards or hazards
arising from the equipment.
All dimensions specified in this Section are shown in mm.
Component
D
Sender/receiver unit DHC-T
Ø 76
Reflector/scattered light receiver DHC-R0
Scattered light receiver DHC-R1
Ø 159
TOP
Assembly on steel duct
A
A
A
A
Marking for assembly position
> 30
a
Ap-
prox
. 1
°
Ø 7
6
Assembly on brick stack
Assembly on thin-walled duct
Junction plate
Anchor plate
Duct wall
Fixing bolt for weatherproof cover
Flange with tube