MENU OVERVIEW
8
Menu overview
Always available
Configuration-dependent
Sub-menu-dependent
Variant-dependent
Failure
Esc
0.00
Set Esc
RUN
DispA
RUN
DispB
RUN
Unit
L/min
L/h
m³/h
G/min
Gal/h
[PRIO1]
RUN
[PRIO2]
RUN
[PRIO3]
RUN
Set
2 s
Q1-##
MEN
Q1-Flw
MEN
Q1-Tmp
MEN
Q1-Sta
MEN
Q1-In
MEN
Esc
Set
Output
SET
Input
SET
Q2-##
MEN
Q2-Flw
MEN
Q2-Tmp
MEN
Q2-Sta
MEN
Q2-In
MEN
Esc
Set
MEN
Q2Mode
MEN
Q2Proc
Esc
Set
Esc
Set
Output
SET
Input
SET
MEN
Q2Func
Esc
Set
Pulse
SET
Freq
SET
Switch
SET
Q2SP
Q2RP
Q2FH
Q2FL
MEN
MEN
MEN
MEN
MEN
Set
Set
Set
Set
###
SET
###
SET
###
SET
###
SET
PlsVal
MEN
Set
ResetV, CutOff
SET
MEN
MEN
MEN
Q2Pol
Q2Sim
Q2Type
Esc
Set
Esc
Set
Esc
Set
no, nc
SET
SimOff, Inactv,
Active
SET
DRV, OC,
NPN, PNP
SET
Q2Stat
MEN
Esc
Set
Fail
SET
Empty
SET
Steril
SET
QaProc
MEN
Esc
Set
Flow
SET
Temp
SET
QaHigh
MEN
QaLow
MEN
Set
Set
###
SET
###
SET
QaPol
MEN
Set
Normal, Invrtd
SET
QaFail
MEN
QaSim
MEN
Esc
Set
Esc
Set
###
SET
###
SET
Qb-##
MEN
Qb-Off
MEN
Qb-Flw
MEN
Qb-Tmp
MEN
Q1Mode
Q1Pol
Q1Sim
Q1Type
Q1Proc
Esc
Set
Esc
Set
Esc
Set
Esc
Set
Esc
Set
Q1Act
MEN
Set
ResetV, CutOff
SET
MEN
Q1SP
MEN
Q1RP
MEN
Q1FH
MEN
Q1FL
MEN
Set
Set
Set
Set
###
SET
###
SET
###
SET
###
SET
Q1Stat
MEN
Fail
SET
Empty
SET
Steril
SET
Set
Set
no, nc
SET
SimOff,
Inactv, Active
SET
DRV, OC,
NPN, PNP
SET
Set
Set
Set
MEN
Set
Set
Set
MEN
MEN
MEN
Negatv
SET
Set
Q1Out
MEN
Esc
Set
Hyst
SET
Window
SET
Set
Set
Set
Set
Flow
SET
Temper
SET
Status
SET
Set
Set
Set
Set
Set
Set
Set
Set
Set
Flow
SET
Temper
SET
Status
SET
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
PlsWid
Esc
Set
Hyst
SET
Window
SET
Set
Set
MEN
FrqMax
Q2Act
Q2Out
FrqMin
Set
Set
Set
Set
###
SET
###
SET
###
SET
###
SET
Set
Set
Set
Set
Set
Set
Set
MEN
MEN
MEN
MEN
Set
Set
Set
Qa-##
MEN
Qa-Off
MEN
Qa-Flw
MEN
Qa-Tmp
MEN
Esc
Set
MEN
QaType
Esc
Set
Off
4 - 20mA
SET
SET
Set
Set
Set
Set
Set
Set
Set
Set
Set
QbProc
MEN
Esc
Set
Flow
SET
Temp
SET
QbHigh
MEN
QbLow
MEN
Set
Set
###
SET
###
SET
QbPol
MEN
Set
Normal, Invrtd
SET
QbFail
MEN
QbSim
MEN
Esc
Set
Esc
Set
###
SET
###
SET
Esc
Set
MEN
QbType
Esc
Set
Off
4 - 20mA
SET
SET
Set
Set
Set
Set
Set
Set
Set
Set
Set
Negatv
SET
Set
Q1Proc
is visible when
Q1Mode
is set as an
Output
.
Q1Act
is visible when
Q1Mode
is set as an
Input
.
Q1Out
is visible when
Q1Mode
is set as an
Output
and
Q1Proc
is set as
Flow
or
Temper
.
Q1SP
and
Q1RP
are visible when
Q1Out
is set as
Hyst
.
Q1FH
and
Q1FL
are visible when
Q1Out
is set as
Window
.
Q1Stat
is visible when
Q1Proc
is set as
Status
.