8.5.6
Defining the RS-422 data protocol
Define the data protocol (only for continuous output,
see "Protocol types and data for
).
Parameter
Factory setting
CR/LF:
CarriageReturn/LineFeed as a separation symbol
CR/LF
STX/ETX:
STX/ETX protocol
8.5.7
Defining the distance value resolution for the RS-422 data transfer
Define the resolution of the distance measured value for continuous output. The dis‐
tance values are output in multiples of the set resolution. The resolution in request
mode is always 1 mm.
Parameter
Factory setting
0.1:
0.1 mm
1 mm
1:
1 mm
10:
10 mm
100:
100 mm
Free input:
0.001 mm ... 1000 mm
8.5.8
Defining the speed value resolution for the RS-422 data transfer
Define the resolution of the speed measured value being output. The speed values are
output in multiples of the set resolution.
8
REFERENCE
84
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK