8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 85
Operating instructions Distance measuring device DL100 Pro – RS-422
Technical data
14.9 Ambient conditions
Protection class
III
Suitable for operation in PELV systems (Protective Extra Low Voltage -
safety extra-low voltage) with secure separation.
Electromagnetic compatibility
1)
EN 61000-6-2, EN 55011, category A
Ambient temperature
See type-specific data
Storage temperature range
–40 °C … +75 °C
Enclosure rating
IP65
Air pressure influence
0.3 ppm/hPa
Temperature influence
1 ppm/K
Temperature drift
Typical 0.1 mm/K
Maximum movement speed
15 m/s
Maximum acceleration
15 m/s²
Vibration resistance (sine)
EN60068-2-6
Noise
EN60068-2-64
Shock resistance
EN 60086-2-27
1) When used in the household area, the device may cause interferences.
Table 59: Ambient conditions
14.10 Constructive setup
Dimensions
→
Weight
• Distance measuring device 800 g
• Alignment bracket (optional): 800 g
Materials
• Casing: Cast aluminum GD-AlSi12Cu1 (3.2982.05)
• Front screen: PMMA
Connections
M12, SpeedCon™
Display
• 6 points with a 5 x 7 point matrix
•
Overflow is displayed with the maximum value that can be displayed,
–99999 or 999999.
Table 60: Constructive setup