Operating instructions Distance measuring device DL100 Pro – RS-422
Operation via Ethernet (Ethernet interface)
60
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
9.2.4
Diagnostic data
Field
Description
Device state
Display device status: ready for operation,warning(s) active,
error active, laser activated, MF1 active and MF2 active.
Read/Write access
• Read only
Device warnings Display of current warnings: Laser, temperature, level and
plausibility.
Read/Write access
• Read only
Device error
Display of current errors: Laser, temperature, level and plausi-
bility.
Read/Write access
• Read only
Level
Display of the current reception level (damping value).
Read/Write access
• Read only
Temperature
Display of current internal device temperature.
Read/Write access
• Read only
Unit
• °C
Operating hours Display of current operating hours.
Read/Write access
• Read only
Unit
• h
Table 30: Page "Diagnostic data"
9.2.5
Parameter settings
NOTE!
Parameter changes only enter into permanent effect if
they are saved via the button "Storage".