Operating instructions Distance measuring device DL100 Pro – RS-422
Operation via Ethernet (Ethernet interface)
56
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
9 Operation via Ethernet (Ethernet interface)
You may parameterize the distance measuring device via the Ethernet
interface with the SICK configuration software SOPAS.
NOTE!
The configuration program SOPAS can be downloaded
9.1
IP-network configuration
IP-network configuration –
delivery configuration
The distance measuring device is delivered with the following IP-network
configuration:
• Static IP-address
• IP address: 192.168.100.236
• IP network mask: 255.255.255.0
• Standard gateway: 192.168.250.100
•
DHCP is off.
Invalid IP address
When the system determines an invalid IP network configuration, the
delivery configuration is used instead.
IP address assigned by DHCP server
You may specify that the IP addresses are assigned by a DHCP server.
When address assignment by the DHCP server fails, the distance
measuring device uses the last set static IP address. If no static IP address
was set yet or if this address is invalid (IP address 0.0.0.0), the delivery
configuration is used instead. This process may take a few minutes.
The following causes for failed address assignment by the DHCP server are
possible:
• No DHCP server present.
• The DHCP server has an interference.
• The DHCP server was not ready yet when the distance measuring device
was switched on.
• The network connection has an interference.