Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
44
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
Menu "RS422"
(continued)
Options
Description
ResSpd
Choose resolution for the output value "Speed" in mm/s
via the digital data interface. The measurement value is
multiplied with the resolution. The parameter does not
influence the measurement value displayed.
Prerequisite
• The parameter is only displayed if the option "Yes" is
selected for the parameter "More".
Options
• 0.1
• 1.0
• 10.0
• 100.0
Factory setting
• 0.1 mm/s
Table 10: Menu "RS422"
8.5.5
Menu "more"
Use the menu "More" to activate and deactivate the expanded menu view.
You can get to the menu "More" via the menu path:
Main menu
→
→
Menu
→
→
RS422
→
→
more
Push the
key for at least 2 seconds to get to the "Menu".
Push the
key. The currently set option is displayed here.
Options
Description
Yes /
No
Active and deactivate expanded menu view.
Options
• Yes
• No
Factory setting
• No
Table 11: Menu "More"