Operating instructions Distance measuring device DL100 Pro – RS-422
Mounting
28
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
6.6
Align distance measuring device and reflector
against each other
1.
Move the distance measuring device and reflector close together.
2. Align the distance measuring device so that the light spot of the sensor
hits the center of the reflector.
3. Increase the distance between the distance measuring device and the
reflector. The sensor light spot must continue to hit the center of the
reflector.
4. Check damping. The damping value must not exceed the value in the
table.
Damping value
The following table shows the required damping values depending on
the distance between the distance measuring device and the reflector.
The values in the "rated level" column should not be undercut. When the
measured damping value undercuts the value in the column "warning
threshold", a warning is issued.
Distance
[m]
Rated level
[dB]
Warning threshold
[dB]
<10
–30
–42
10
–30
–42
20
–42
–54
35
–54
–66
70
–66
–78
150
1)
–78
–90
300
2)
–90
–102
1) For distance measuring devices with a measurement range of 0.15 ... 200 m or
0.15 ... 300 m
2) For distance measuring devices with a measurement range of 0.15 ... 300 m
Table 4: Damping values