13
Technical data
13.1
Data sheet
General system data
Table 31: General system data
Minimum
Typical
Maximum
Beam separation, depending on type 500 mm or 300 mm
Number of beams, depending on
type
2 or 4
Resolution
30 mm
Dimension of the light path, depending on type
1)
2)
3)
4)
Passive unit for short scanning ranges
System with 2 beams
3 m
3.2 m
System with 4 beams
3 m
3.2 m
Passive unit for long ranges
System with 2 beams
8 m
8 m
System with 4 beams
7 m
7 m
Minimum distance between active and passive units
Passive unit for short scanning range
System with 2 or 4 beams
0.5 m
Passive unit for long range
System with 2 or 4 beams
0.5 m
Protection class
5)
III (IEC 61140)
Enclosure rating
6)
IP 65 (IEC 60529)
IP 67 (IEC 60529)
Supply voltage
7)
8)
9)
24 V DC (19.2 V DC … 28.8 V DC)
Residual ripple
10)
± 10 %
Power consumption
4 W
Type
Type 4 (IEC 61496-1)
Category
Category 4 (ISO 13849-1)
Performance level
11)
PL e (ISO 13849–1)
Safety integrity level
11)
SIL3 (IEC 61508)
SIL claim limit
11)
SILCL3 (IEC 62061)
PFHd (mean probability of one dan‐
gerous failure per hour)
12)
6.6 × 10
-9
T
M
(mission time)
20 years (ISO 13849-1)
Safe status when a fault occurs
At least one OSSD is in the OFF state.
Power-up delay after supply voltage
applied
13)
2 s
Time monitoring for muting
Sensor gap monitoring (muting sen‐
sor and ESPE)
0.5 s
Muting end delay
0.2 s
Total time end of muting by ESPE
14)
0.7 s
0.725 s
Muting hold time
4 s
13
TECHNICAL DATA
98
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
8024782/2019-11-19 | SICK
Subject to change without notice