Minimum
Typical
Maximum
Output voltage HIGH (active)
U
v
– 3 V
Output voltage LOW (deactivated)
High resistance
Output current HIGH (active)
100 mA
Permissible cable resistance
5)
Supply cable
2 Ω
Cable between OSSD and load
2.5 Ω
All additional wires at the system
connection and extension connection
2.5 Ω
1)
Applies to the voltage range between -30 V and +30 V.
2)
According to IEC 61131-2.
3)
The specified values are the switching voltage supplied by the device. If higher voltages are impressed
externally, the maximum value of 2.0 V can be exceeded.
4)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers,
make sure that the test pulses do not result in deactivation when using the above parameters.
5)
Limit the cable length to the specified values to ensure that the protective device functions correctly, par‐
ticularly that a cross-circuit between the outputs is safely detected. (Also observe IEC 60204-1.) The
specified values apply to the total resistance of each wire including contact and connector resistances.
13.2
Length of cable
Table 34: Connection cables for active unit
Single system
Maximum lengths of cable for wire cross-sec‐
tion 0.34 mm
2
, copper wire
b
S
b = 40 m
Maximum lengths of cable for wire cross-sec‐
tion 0.25 mm
2
, copper wire
b
S
b = 25 m
S
Control cabinet with safety relay or safety controller
13.3
Table of weights
Table 35: Weight of the active unit without integrated LED
Number of beams
Weight in g
1)
2
550
4
875
1)
Tolerance: ± 50 g
Table 36: Weight of the active unit with integrated LED
Number of beams
Weight in g
1)
2
565
4
890
1)
Tolerance: ± 50 g
TECHNICAL DATA
13
8024782/2019-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
101