18
DEFOR · Supplementary Operating Instructions · 8013029 V2.0 · © SICK AG
Functions in SOPAS ET
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
4.3
Explanation of functions
4.3.1
Logbook in SOPAS ET
The Logbook Table shows the last 20 internal messages.
Fig. 3
Menu “
[Module name]
/Diagnosis/Logbook” in PC program “SOPAS-ET” (example)
4.3.2
Upload (data synchronization)
Only applicable when the “SOPAS ET” PC software is used. Not applicable for systems
without control unit (special versions).
The new data are not transferred automatically to “SOPAS ET” after settings for a module
have been changed with the menu functions of the control unit. “SOPAS ET” continues
using the previous data.
▸
To transfer the current data of a module to “SOPAS ET
”
:
Start the “Upload all parame-
ters from device” function in “SOPAS ET” once.
Column Meaning
1
Sequential number in Logbook
2
Time of last message change
3
4
“System” = measuring system (hardware)
“MV” = measuring component (measurement)
5
Short message text, e.g. “F measured value”.
The character prefix classifies the message:
F = Failure
C = Check (adjustment/validation)
U = Uncertain (extra information)
M = Maintenance
E = Extended (status message)
6
Current message status
7
Total count of activations
1
2
3
4
5
6
7