Chapter
3
Operating Instructions
CLV640 Bar Code Scanner
20
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Quick-Start
3.3
Performing the reading
Fig. 3-1:
Register tab Quickstart
Perform the reading:
1. Ensure that the relevant code types are activated on the register tab.
2. Carry out a test reading with a test bar code.
To achieve this, hold an object with a bar code in front of the bar code scanner's reading
window and trigger the reading by clicking S
TART
. The default setting of the focus posi-
tion is 285 mm (11.2 in). If necessary, observe the bar code scanner's depth of fields
ranges in relation to the resolution (see
chapter 10.3 Specification diagrams,
).
During reading operation and with default settings, the line scanner with oscillating mir-
ror deflects the scanning line by the central position with a frequency of 1 Hz and at a
max. angle of ± 20°.
The reading result is displayed in the B
ARCODE
C
ONTENT
display field.
The code reading reliability is specified in the relevant display field.
Note
With the SOPAS-ET configuration software, the Q
UICKSTART
register tab contains the most im-
portant reading parameters for configuring and performing a bar code reading:
P
ROJECT
T
REE
, CLV640, Q
UICKSTART
register tab