![SICK CLV61 DualPort Series Operating Instructions Manual Download Page 64](http://html.mh-extra.com/html/sick/clv61-dualport-series/clv61-dualport-series_operating-instructions-manual_1264234064.webp)
12.5
Ambient data
Table 20: Technical data for ambient data
CLV610
CLV612
CLV615
Electromagnetic com‐
patibility (EMC)
Radiated emission: EN 61000-6-4: 2007-01 + A1: 2011-02
Electromagnetic immunity: EN 61000-6-2: 2005-08
Vibration resistance
EN 60068-2-6: 2008-02
Shock resistance
EN 60068-2-27: 2009-05
Ambient operating
temperature
0 °C ... +40 °C
Storage temperature
‒20 °C ... +70 °C
Permissible relative
humidity
0% ... 90%, non-condensing
Ambient light immun‐
ity
2000
lx, on bar code
Bar code print con‐
trast (PCS)
≥
60
%
12.6
Dimensional drawings
.
12.7
Reading field diagrams (working ranges)
12.7.1
Reading conditions for specification diagrams
Properties
Value
Test code
Code 39 / ITF
Resolution
See reading field diagrams in each case
Scanning frequency
See characteristic curve fields for scanning frequencies
Print ratio
2:1
Print contrast
> 90%
Tilt
±
30°
Ambient light
< 2,000 lx
Good read rate
> 75%
Light spot
Circular
Window material of the
viewing window
Glass (CLV61x-xxx
0
)
NOTE
The reading distances are measured radially from the device.
12
TECHNICAL DATA
64
O P E R A T I N G I N S T R U C T I O N S | CLV61x
8017840/19OF/2021-10-28 | SICK
Subject to change without notice