PIN
Signal
Function
3
GND
Ground
4
Reserved
(Do not use)
5
Sensor 1
Digital input for external reading cycle
6.4
Wiring interfaces
6.4.1
Connecting the supply voltage
Connecting supply voltage to devices without heating
Connect the device only to a power supply unit that has the following properties:
•
Stabilized safety extra-low voltage SELV according to currently valid standards
•
The voltage supply must meet the requirements of ES1 (EN 62368-1).
•
Supply voltage 10 V DC ... 30 V DC
•
Electricity source with at least 30 W power
Connecting supply voltage to devices with heating
•
Stabilized safety extra-low voltage SELV according to currently valid standards
•
The voltage supply must meet the requirements of ES1 (EN 62368-1).
•
Supply voltage 18 V DC ... 30 V DC
•
Electricity source with at least 40 W power
Protecting the supply cables
To ensure protection against short-circuits/overload in the customer’s supply cable,
appropriately choose and protect the wire cross-sections used and at the beginning of
the supply cable.
Observe the following standards in Germany:
•
DIN VDE 0100 (part 430)
•
DIN VDE 0298 (part 4) and/or DIN VDE 0891 (part 1)
Supply voltage directly via a SICK connection module or via customer-side supply
voltage.
6.4.2
Wiring the PROFINET interface
1.
Connect the device using the pre-assembled cables to the left and right of the
additional devices (IO devices) in the PROFINET network. Line or ring topology
is possible. If only one Ethernet connection is needed (e.g., last device in a line
topology), either the P1 or P2 connection can be used. Fit a protective element of
the appropriate design onto the unused connection (as in delivery condition).
2.
Switch on the supply voltage for the device. The device starts with a delay and
uses the default parameters set in the factory for the initialization. After a suc‐
cessful self-test, the blue LED on the device lights up to indicate the “Device
Ready” status.
ELECTRICAL INSTALLATION
6
8017842/19XD/2021-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x DualPort (PROFINET)
47