Operating Instructions
Chapter
5
CLV 490 Bar Code Scanner
8 009 993/O824/20-12-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-19
Electrical installation
5.5
Electrical installation procedure
5.5.1
Individual steps
•
Connect the power supply
•
Connect the host interface
•
Connect the PC (connect the terminal interface)
•
Connect the "Sensor" and "IN 0" to "IN 4" switching inputs
•
Connect the "Result 1" to "Result 4" switching outputs
5.5.2
Tools
•
Tool
•
Digital measuring device (current/voltage measurement)
5.5.3
Connecting the supply voltage
a) SICK CDB 420 or CDM 490 Connection Module
If the CLV is powered via the SICK Connection Modules using the cables no. 2 027 046,
no. 2 030 023, no. 2 020 307, or no. 2 027 543, the supply voltage does not have to be
wired separately.
Using the cables with open ends no. 2 033 126, no. 2 033 127, no. 2 030 065, or
no. 2 031 034, the supply voltage must be wired separately at the screw terminal strips in
the connection module.
Connecting the CLV without connector cover:
1.
Make sure that the power supply to the connection module is switched off.
2.
Connect the "Host/Term" and "I/O" connections on the CLV to the corresponding con-
nections on the CDM 490 Connection Module using two cables no. 2 020 302 or no.
2 021 815 and secure them tightly on both sides.
Connecting the CLV with connector cover/connector cover with parameter memory:
1.
Connect the connector cover of the cable no. 2 027 046, no. 2 030 023,
no. 2 033 126, or no. 2 033 127 to the "Host/Term" and "I/O" connections on the CLV
and secure it tightly.
2.
Connect the free 15-pin cable plug to the corresponding socket on the CDB 420
Connection Module and secure them tightly.
For the cable no. 2 033 126 or no. 2 033 127, lead additionally the cable with open
end through one of the cable glands and connect it to the screw terminals 3, 4, and 6.
– or –
1.
Connect the connector cover of the cable no. 2 020 307, no. 2 030 065,
no. 2 031 034, or no. 2 027 543 to the "Host/Term" and "I/O" connections on the CLV
and secure it tightly.
2.
Connect the free 15-pin cable connections to the corresponding connections on the
CDM 490 Connection Module and secure them tightly.
For the cable no. 2 030 065 or no. 2 031 034, lead additionally the cable with open
end through one of the cable glands and connect it to the screw terminals 3, 4, and 6.
The data and function interfaces of the CLV are connected to the Connection Module.