Operating Instructions
Chapter
10
CLV 490 Bar Code Scanner
8 009 993/O824/20-12-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-39
Appendix
10.3.8
Replacing a CLV
The device is replaced by starting the new CLV with the S
TART
WITH
E
XTERNAL
P
ARAMETERS
op-
tion (default). This is the case when the device is put into service for the first time, e. g. when
it is taken from the warehouse. The device must be replaced with a device of the same type.
You do not need to connect a PC to replace the device.
¾
Replace the device as described in
Chapter 10.12.2 Importing the parameter set from
the external memory, Page 10-74
The CLV imports the external parameter set into the RAM. This is sufficient to ensure that
the device operates correctly. If the parameter set is to be stored permanently in the CLV
(EEPROM), a PC with the "CLV-Setup" program must be connected to upload the parameter
set from the CLV to CLV-Setup and then download it again to the CLV with the P
ERMANENT
storage option. When asked to do so, adjust the external memory again.