Chapter
6
Operating Instructions
CLV 490 Bar Code Scanner
6-28
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Operation
A2. Tracking mode (controlled by Increment)
•
Max.
10 consecutive objects
in conveyor direction simultanously in the reading field,
reading one side with internal object tracking
Conditions:
•
Minimum object gap between two objects in conveyor direction:
50 mm (1.97 in)
•
Size of reading field = distance between sensor for beginning/end of object and object
release point parameterized (data output)
•
Autofocus mode "Differential background and tracking“, see
event-controlled focus position switchover
•
Incremental encoder connected to "IN 4" switching input
Possible reading triggers:
•
One external sensor (e. g. photoelectric reflex switch)
•
Command strings
Further preparations:
¾
Configuring reading area: see
Chapter a)Parameterizing reading area, Page 6-10
.
¾
Selecting focus control mode: see
Chapter b) Selecting focus control mode,
.
¾
Configuring focus control: see
Chapter c) Parameterizing focus control, Page 6-12
.
¾
Configuring oscillating mirror (optional): see
Chapter e) Parameterizing oscillation mirror
functions (optional), Page 6-18
.
¾
Configuring no. of bar codes to be read: see
Chapter h) Parameterizing the evaluation
Note
To separate bar codes of the same type with identical contents, connect an incremental
encoder and activate the "Compare Code Position" function. See also
Activating and parameterizing internal object tracking:
Action
Settings in CLV-Setup
1. Parameterize internal object
tracking
Ö
D
EVICE
CONFIGURATION
tab
Ö
I
NTERNAL
T
RACKING
S
ection
– active
Ö
D
ISTANCE
PER
ENCODER
PULSE
S
ection
– Value: according to encoder resolution
Ö
T
RACKING
P
ARAMETERS
button
Ö
RELEASE
POINTS
S
ection
– Focus release point
– Object release point/End of reading field/Output data
Ö
L
ABEL
A
SSIGNMENT
T
OLERANCE
S
ection
– Automatic (default setting)
or
– Fix Tolerance: value
Ö
R
EADING
CONFIGURATION
tab
Ö
A
UTOFOCUS
P
ARAMETERS
button
Ö
A
UTOFOCUS
P
ARAMETERS
tab
– C
ODE
BASED
F
OCUS
RELEASE
IF
...
S
ection
– Number of codes equals Minimum
or
– Number of codes equals Maximum
or
– Number of codes exeeds Maximum
Table 6-12: Guide: Parameterzing internal object tracking