Chapter
6
Operating Instructions
CLV 45x Bar Code Scanner
6-16
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 139/K949/06-06-2002
Operation
(default setting). To begin with it only overwrites the appropriate parameter values in the
RAM.
The CLV returns to the Reading mode with the decoder parameterized for this purpose.
The "Device Ready" LED lights up. The R
EADING
MODE
radio button in the terminal emu-
lator is not, however, displayed as the active device mode again.
The CLV only evaluates the presented code type and length in further readings.
6.
Uploading from the CLV To do so, click on
in the toolbar.
CLV loads the current parameter record from the RAM of the CLV and displays the new
values in the tab cards.
7.
Carry out the download to the CLV. To do so, click on
in the toolbar.
The D
OWNLOAD
PARAMETERS
dialog box is opened.
8.
Confirm the dialog box with the saving option P
ERMANENT
.
The CLV saves the changes made to the parameter record permanently in the EEPROM.
9.
Close the terminal emulator.
Terminating Auto Setup by the CLV in the event of a no read
If the CLV was not able to execute Auto Setup successfully, it terminates the search mode
after the last increase made to the parameter values by outputting a long acoustic signal via
the beeper.
Depending on the reason for Auto Setup being terminated, it outputs one of the following
error messages via the terminal interface:
With:
FocPos
= Focal position
Step
= Motor step for focal position adjustment
Amp
= Amplifier setting
ScanFreq
= Scanning frequency
ReadRate
= Reading quality
CodeType
= Code type
CodeLen
= Code length
CodeStr
= Data contents of the bar code
Fig. 6-6:
CLV-Setup: Displaying the course of the Auto Setup in the terminal emulator