Operating Instructions
Chapter
10
CLV 45x Bar Code Scanner
Appendix
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-49
10.9.8
Connection to Ethernet
Refer to
Operating Instructions "BMV/BMH 10 for Ethernet"
(Order No. 8 009 398, English edition)
10.9.9
Building a CAN Scanner Network
Refer to
Operating instructions "Application of the CAN interface"
(Order No. 8 009 180, English edition)
10.10 Replacing a CLV (copying the parameter record)
There are two methods of replacing a CLV and transferring the current parameter record to
the new device:
•
Transferring the parameter record using the Profile bar codes
•
Transferring by means of a download from CLV-Setup
The parameter record can only be transferred between identical device types (e. g. from
CLV 45x to another CLV 45x, etc.).
10.10.1 Transferring the parameter set using Profile bar codes
You do not need to connect the device to a PC in order to transfer the parameter record
using the Profile bar codes. The parameter record of the CLV that is to be replaced must be
available in the form of an archived Profile bar code print or at least as a configuration file in
CLV-Setup. Otherwise the replacement device has to be reconfigured.
The procedure for printing out the Profile bar codes is described in
1.
Disconnect the supply voltage of the AMV/S 40 connection module (of the CLV).
2.
Disconnect and remove the CLV cable plug from the AMV/S 40.
3.
Remove the CLV from the retainer.
Before doing so, mark the position and alignment on the retainer or surroundings.
4.
Mount, align, and connect the replacement device.
5.
Switch on the supply voltage of the AMV/S 40.
The "Device Ready" LED lights up. The CLV outputs an acoustic signal to indicate that
it is ready to read the Profile bar codes.
6.
Present the first Profile bar code
within 5 seconds
.
The CLV confirms the successful read by emitting an acoustic signal and waits
10 seconds
for the next Profile bar code.
7.
Present all the further Profile bar codes consecutively in the
printed sequence
.
8.
Then allow the final wait time of 10 seconds to elapse.
The CLV outputs two consecutive acoustic signals to indicate that it has switched to
Reading mode.
The new CLV is now ready to use the transferred parameter record.
Help in cases of problems
If the software version on the replacement device is older than the version on the old device
(e. g. new device is from warehouse stock), the Profile bar codes may contain coded
parameters or parameter values that cannot be interpreted by the older software of the
replacement device. However, the CLV reads all of the Profile bar codes, without anything
being said about the ability to be interpreted.
¾
Check the functionality of the replaced CLV by means of the CLV-Setup user interface.