CLV messages
The CLV outputs system messages, warnings and error messages in English in response to
the actions carried out by the user. The messages are output in plain text via the terminal
interface only.
6.6.1
Displaying messages
To display the messages on the PC in the CLV Setup user interface, proceed as follows:
1.
Click
in the toolbar.
The terminal emulator window is then displayed.
2.
In the T
ERMINAL
M
ODE
group, click the E
XTENDED
radio button.
The CLV then outputs messages in response to events that occur while the bar code is
being read. The messages are only output in the
extended mode
of the terminal emulator!
6.6.2
System messages
System messages confirm that an action has been carried out successfully, e.g. changing
the operating mode. No other actions are required here.
Chapter 10.3 System messages, Page 10-6
explains the contents of the messages.
6.6.3
Warnings
Warnings indicate that it was not possible to perform an action or that the values set for the
parameters can cause an error while the bar code is being read.
6.6.4
Error messages
Error messages indicate the following error sources:
•
a device defect
•
incorrect parameter settings
•
errors during data transfer to the host
Chapter 8.3 Error messages, Page 8-2
lists the messages in alphabetical order together
with the associated corrective measures.
Message
Meaning
Remedy
"Warning: Master Timeout"
Duration of the set master timeout is too short
Optimize the master timeout using the D
EVICE
C
ONFIGURATION
tab in the user interface of CLV
Setup. Download to the CLV!
(see also
technical information "Master/Slave
with CLV Bar Code Scanners", no. 8 007 675,
English version
)
Table 6-7: Warnings