CONFIGURATION DEFAULTS
Parameter
Reading Configuration
Scan Frequency (Hz)
Minimum Bar Width
Minimum Dist.
Maximum Dist.
Segmentation
Clock Pulse - Source Clock Pulse
Minimum CP
Maximum CP
Switching Outputs:
1
Result Output
2
Match Code
3
Device ID Number
Master/Slave
Setting
CLV 410 / 412
500 Hz
50 mm (.020)
40 mm (1.6 in)
Start Stop Ratio
Reflector Polling
End Clock Pulse
0
100
Device Ready
90 Read
No Read
1
Stand alone
Parameter
Code Type
Code Length
Multiple Reads
Check Digit Test
Transmit Check Digit
Transmit Start / Stop
Identical Start / Stop
Transmit Leading Zero
Add-On
Full ASCII
Output Hex-ASCII
FCI First Char.
FCI in Code String
Code Type
Code 39
Active
Free
3
No
Yes
No
-
-
-
No
No
-
-
Int. 2/5
Active
Free
3
No
Yes
-
-
Yes
-
-
-
-
-
EAN
8-digit active
13-digit active
-
3
-
Yes
-
-
-
None
-
-
-
-
UPC
Version A ON
Version E ON
-
3
3
Yes
-
-
-
None
-
-
-
-
Codabar
Active
Free
3
No
Yes
No
No
-
-
-
-
-
-
Code 128
Active
Free
3
-
-
-
-
-
-
-
No
-
-
Code 93
Active
Free
3
No
-
-
EAN 128
Active
Free
3
No
5D4331 hex
ID0000 hex
Code Configuration
Decoder
Min. No. of Codes
Max. No. of Codes
CP - Comp. Multir.
Min. Dist. Labels
T - Code Labels
Multiple codes on object
Standard
1
1
yes
50 mm
No
No
Default Configurations for Each Bar Code Type:
Default Configurations for Each Bar Code Type: