4
Description
Abbre-
Function
Determination
Transmission
Figure
viation
in block
Scan
CA
• Indicates total number of scans required
For every bar
_
4-4
Expenditure
to fulfill specified number of multiple reads
code in a single
(identical scans)
reading gate
Total Scan
GCA
• Internal arithmetical number representing the
_
4-4
Expenditure
number of all scans taking place in period
between first and last identical scans The
number depends both on the bar code quality
and on the specified transmission time
(sending point) of bar code data
Identification
CG
• Indicates relative measure of quality for
Separator
4-4
Quality
reading status for one reading gate. The
decoder calculates this value as follows:
CS
CG = –––––– x 100%
GCA
Reading Gate TT
• Indicates length of time from the beginning of
For every
Terminator
–
Duration
the reading gate until evaluation criteria are met reading gate
for all bar gate code labels encountered.
Number of
CC
• Indicates number of all bar code labels detected
Header /
_
Codes
according to selection criteria
Terminator
Detected
Device ID
GN
• Indicates the CLV identification number in a
Terminator
_
Number
CLX 200 network configuration
Average
MG
• Indicates average value of identification quality
Header
_
Reading
(CG) from preceding reading gates
Evaluation
The decoder calculates this value as follows:
(a x MG
old
) - (b x CGM)
MG
new
= —————————————
(a-b)
a = 63
b = 1
(63 x MG
old
) - (1 x CGM)
MG
new
= —————————————— %
64
• The average value provides a trend indication
for the reading performance of the CLV from
preceding period up to the present