S o f t w a r e C o n f i g u r a t i o n s
46
S
I
C
K
O
p
t
i
c
-
E
l
e
c
t
r
o
n
i
c
B
a
r
C
o
d
e
S
c
a
n
n
e
r
s
3
Sending Points
This function allows the user to determine when the scanner should send bar code data and separators to the host. Refer to
Figure 3-28.
(immediately/end of reading/pulse/end of label)
If “immediately” is selected, the CLV will send the bar code data to the host immediately after a successful read. If “end of reading
pulse” is selected, the CLV will send the bar code data after the clock pulse reading gate has ended. If “end of label” is selected,
the CLV will send the bar code data to the host and end the reading gate after the read bar code has moved outside the reading
range of the CLV for at least the programmed time value.
Separator Position
(After/Before Code)
If “After” is selected, the CLV will send the separator string after the code is sent. If “Before” is selected, the separator will be sent
before the code data. Refer to Figure 4-2 for examples of each separator position.
Figure 3-28 Sending Points of Bar Code Data
Time of output specified
by parameterization:
Output immediately
after read.
Output at end
of reading gate
(clock pulse)
Reading gate
Successful reading gate
Unsuccessful reading gate
Successful reading gate
Unsuccessful reading gate