“No Read”
- Active if the CLV has not found a code which matches the defined settings for code type, code length and check
digit at the end of the reading gate.
Note: If a code is read but does not meet Multiple Reads criteria (ST=5), the no read condition will not be activated. For this
situation, it is recommended to use a Number of Codes < Minimum Codes instead of “No Read” setting.
“Good Read”-
Active if the following defined read conditions are fulfilled by the codes read at the end of the reading gate:
- Code type
- Code length
- Number of multiple reads
- Check digit
- Number of codes = minimum number of codes
“Data Pulse”-
This output data is being transmitted to the host device. Does not adhere to Timer condition, since it is only
active when data is being transmitted.
“Number of Codes < Minimum Codes”-
Active if the number of codes read that fulfill the evaluation criteria is less than the
specified minimum value. Outputs assigned to switching functions “Good Read” and “No Read” remain active in this case.
“Number of Codes > Maximum Codes” -
Active if the number of codes read that fulfill the evaluation criteria is greater
than the specified maximum value. Outputs assigned to switching functions “Good Read” and “No Read” remain active in this
case.
“No Match” -
Active if none of the read codes match the settings for match code 1 or 2. (Prerequisite: Comparison for both
code 1 or code 2 activated)
“Match 1” -
Activate if at least one of the codes read matches the settings for match code 1. (Prerequisite: Comparison for
code 1 activated) “Mismatch 1”- Active if none of the read codes match the settings for match code 1. (Prerequisite: Comparison
for code 1 activated and Good Read).
“Match 2” -
Active if at least one of the read codes matches the settings for match code 2 (Prerequisite: Comparison for code 2
activated).
“Mismatch 2”-
Active if none of the read codes match the settings for match code 2 (Prerequisite: comparison for code 2
activated and Good Read).
“Match 1 or 2” -
Active if the settings for match code 1 or the settings for match code 2 or both are fulfilled.
“Match 1 and 2” -
Active if the settings for both match code 1 and match code 2 are fulfilled.
Pulse Duration -
(10 x (.01s) 10 ms to 990 ms )
This sets the pulse duration of all discrete outputs. The “00” setting causes the outputs to switch statically, i.e. the outputs change
state at the end of the reading gates only.
Invert #1...#3 -
Invert switches The active output from High to GND. The normal condition switches the active output from
High to GND.