TECHNICAL DATA
14.4
Mechanics/materials
Materials in contact with the media
Outer tube: polypropylene (PP-H)
G 3/4": PBT
3/4'' NPT: PBT
Easy Clamp Bracket: PP
Process connection
G 3/4" A
3/4'' NPT
without process connection
Housing material
PBT and PC
Max. probe load
≤ 4 Nm
Enclosure rating
IP 65 / IP 67: EN 60529
Weight
max. 500 g
14.5
Reference conditions
Air humidity
65% (± 20%)
Temperature
20 °C (± 5 °C)
Water (DC = 80)
Medium
Distance to built-in components: 60 mm
Centered installation of sensor
Distance to bottom of the tank: 10 mm
Container parameterization carried out
CalEmp completed
14.6
Ambient conditions
Ambient temperature, operation
1)
–20 °C … +60 °C
Ambient temperature, storage
–40 °C … +80 °C
1)
According to UL listing: degree of contamination 3 (UL61010-1: 2012-05); air humidity:
80% at temperatures up to 31 °C; installation height: max. 3,000 m above sea level; only for