![SICK C4000 Select Operating Instructions Manual Download Page 78](http://html.mh-extra.com/html/sick/c4000-select/c4000-select_operating-instructions-manual_1264351078.webp)
Chapter
13
Operating Instructions
C4000 Select
78
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8012247/RI61/2007-11-30
Annex
13.2
Checklist for the manufacturer
Checklist for the manufacturer/OEM for the installation of electro-sensitive
protective equipment (ESPE)
The details on the items listed below must be available at the latest when the system is commissioned for the first
time, depending, however, on the various applications the requirements of which must be reviewed by the manufac-
turer/OEM.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring
tests.
1.
Have the safety rules and regulations been observed in compliance with the
directives/standards applicable to the machine?
Yes
No
2.
Are the applied directives and standards listed in the declaration of conformity?
Yes
No
3.
Does the protective device comply with the required category according to EN 954
@
1?
Yes
No
4.
Is the access to the hazardous area/hazardous point only possible through the protective field of
the ESPE?
Yes
No
5.
Have appropriate measures been taken to prevent (mechanical point-of-operation guarding)
or monitor unprotected presence in the hazardous area when protecting a hazardous area/
hazardous point and have these been secured against removal?
Yes
No
6.
Are additional mechanical protective measures fitted and secured against manipulation which
prevent reaching under, over or around the ESPE?
Yes
No
7.
Has the maximum shutdown and/or stopping time of the machine been measured, specified
and documented (at the machine and/or in the machine documentation)?
Yes
No
8.
Has the ESPE been mounted such that the required safety distance from the nearest hazardous
point has been achieved?
Yes
No
9.
Are the ESPE devices correctly mounted and secured against manipulation after adjustment?
Yes
No
10.
Are the required protective measures against electric shock in effect (protection class)?
Yes
No
11.
Is the command device for resetting the protective devices (ESPE) or restarting the machine
present and correctly installed?
Yes
No
12.
Are the outputs of the ESPE (OSSDs) integrated in compliance with the required category
according to EN 954
@
1 and does the integration comply with the circuit diagrams?
Yes
No
13.
Has the protective function been checked in compliance with the test notes of this
documentation?
Yes
No
14.
Are the given protective functions effective at every setting of the operating mode selector
switch?
Yes
No
15.
Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored?
Yes
No
16.
Is the ESPE effective over the entire period of the dangerous state?
Yes
No
17.
Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when
changing the operating mode, or when switching to another protective device?
Yes
No
18.
Has the information label “Important Information” for the daily check been attached so that it is
well visible for the operator?
Yes
No
This checklist does not replace the initial commissioning, nor the regular inspection by qualified safety personnel.