![SICK C4000 Select Operating Instructions Manual Download Page 19](http://html.mh-extra.com/html/sick/c4000-select/c4000-select_operating-instructions-manual_1264351019.webp)
Operating Instructions
Chapter
3
C4000 Select
8012247/RI61/2007-11-30
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
19
Product description
3.4.2
Message center of the C4000 Select receiver unit
The message center for the C4000 Select receiver unit consists of several LED groups and
a 7
@
segment LED display that provides operational status as shown in the figure below:
LED Name
Display
Meaning
Green
Output signal switching devices (OSSD)/safety outputs
are ON
Red
Output signal switching devices (OSSD)/safety outputs
are OFF
OUTPUT
Off
No power is currently supplied to the receiver unit
Red
Extended I/O safety inputs are
Inactive
(Low) i.e. OFF
EXT I/O
Off
Extended I/O safety inputs are
Active
(High) i.e. ON or
Extended I/O has been disabled
Yellow
Blanking is active
BLANKING
Off
Blanking is inactive
Yellow
Indicates that one or more beams are aligned between sen-
der and receiver units. The first LED will be
Yellow
when
one of the synchronization beams has been aligned. When
all five (5) LEDs are
Yellow
, this indicates all beams are
aligned between sender and receiver units, but there is a
weak signal.
ALIGNMENT
LEDs
Green
When all five (5) LEDs are
Green
, this indicates that all
beams are aligned between sender and receiver units.
An internal error has been detected. Replace receiver unit.
Check DIP switch settings
Optical signals have been detected from multiple sender
units. Change beam code of this C4000 Select
sender/receiver pair.
Check power supply voltage
Check system wiring for errors
7
?
segment
display
Check extended I/O wiring for errors
Fig. 10: Message center for
C4000 Select receiver unit
Tab. 2: C4000 Select recei-
ver LED display indication