background image

3

Mounting

This chapter contains instructions on how to mount the safety light curtain.

An optional alignment bracket is also available with extended adjustment possibilities,

see "Accessories", page 29

.

NOTE

Mount the safety light curtain in the following order.

3.1

Safety

In addition to the information in the underlying operating instructions, please observe
the following points when mounting the safety light curtain.

DANGER

Risk of ignition or explosion

b

Disconnect the voltage supply before starting to mount the explosion-proof enclo‐
sure to avoid igniting hazardous atmospheres.

b

Only reconnect the voltage supply once you have completed the mounting process.

DANGER

Risk of ignition or explosion

b

If you have to remove the cover when working on the safety light curtain, make
sure that the joints and o-ring are clean and undamaged before refitting the cover.

DANGER

Risk of ignition or explosion

b

The safety light curtain must be mounted so that there is a gap of more than
30

 

mm between all other objects and the flange joints between the housing and

the cover.

DANGER

Dangerous state of the machine

b

Make sure that the dangerous state of the machine is (and remains) switched off
during mounting, electrical installation, and commissioning.

b

Make sure that the outputs of the safety light curtain do not affect the machine
during mounting, electrical installation, and commissioning.

DANGER

Risk of ineffectiveness of the protective device
Persons or parts of the body to be protected are not recognized in case of non-obser‐
vance.

b

Only use brackets recommended by SICK for mounting.

b

Take appropriate measures for vibration dampening if the vibration and shock
requirements are above the values and test conditions specified in the data sheet,

see "Data sheet", page 24

.

MOUNTING

8

O P E R A T I N G   I N S T R U C T I O N S | C4000 Fusion Ex

8022867/2019-03-04 | SICK

Subject to change without notice

Summary of Contents for C4000 Fusion Ex

Page 1: ...O P E R A T I N G I N S T R U C T I O N S C4000 Fusion Ex Safety light curtain...

Page 2: ...sible within the limits of the legal determination of Copyright Law Any modifica tion abridgment or translation of this document is prohibited without the express writ ten permission of SICK AG The tr...

Page 3: ...g the safety light curtain 13 4 Electrical installation 20 4 1 Safety 20 5 Aligning the sender and receiver 21 6 Maintenance 23 6 1 Regular cleaning 23 7 Technical data 24 7 1 Data sheet 24 7 2 Table...

Page 4: ...y valid in conjunction with the underlying operating instructions C4000 Palletizer Standard Advanced Safety Light Curtain C4000 Fusion SICK part number 8012249 change index YT69 or newer Unless otherw...

Page 5: ...lass III The C4000 Fusion Ex safety light curtain also complies with these standards EN 60079 0 2012 A11 2013 IEC 60079 0 Edition 6 0 EN 60079 1 2014 IEC 60079 1 Edition 7 0 EN 60079 31 2014 IEC 60079...

Page 6: ...b environments DANGER Risk of ignition Failure to observe this information could result in a risk of ignition Only if the device is used in North America b Any conduit openings that are not in use mus...

Page 7: ...ulations and guidelines are complied with b These operating instructions must be made available to the operator of the machine on which the safety light curtain is used Qualified safety personnel must...

Page 8: ...ing the cover DANGER Risk of ignition or explosion b The safety light curtain must be mounted so that there is a gap of more than 30 mm between all other objects and the flange joints between the hous...

Page 9: ...proof enclo sure to avoid igniting hazardous atmospheres b Only reconnect the voltage supply once you have completed the mounting process DANGER Risk of ignition or explosion b If you have to remove t...

Page 10: ...swivel mount brackets to the upper and lower end caps on the safety light curtain 3 Mount the mounting bracket onto the riser using the fixing screws supplied Align the mounting bracket with the two l...

Page 11: ...ure 2 Align the safety light curtain in the explosion proof enclosure 1 Measure the distance from the end of the cover to the first rib 2 Detailed view MOUNTING 3 8022867 2019 03 04 SICK O P E R A T I...

Page 12: ...ount the gland see Mount ing the optional cable gland page 12 14 Fit the cover to the explosion proof enclosure using the supplied fixing screws and washers Tighten the fixing screws with a torque of...

Page 13: ...the connecting cable must point in the same direction for both devices Figure 4 The sender and receiver are mounted incorrectly b Sender and receiver must not be installed at 180 rotated relative to e...

Page 14: ...red tools Figure 5 Mounting the safety light curtain without the alignment bracket b Use wrench size 13 mm Figure 6 Mounting the safety light curtain without the alignment bracket Step 1 1 Using 6 to...

Page 15: ...over the partly tightened screws Figure 8 Mounting the safety light curtain without the alignment bracket Steps 3 and 4 3 Fix the upper end of the explosion proof enclosure to the mounting surface usi...

Page 16: ...4 x WS 13 mm Scope of delivery Required tools Figure 9 Mounting the safety light curtain using the alignment brackets Figure 10 Assembling the alignment brackets 3 MOUNTING 16 O P E R A T I N G I N S...

Page 17: ...crew into the through hole 6 Rotate the upper alignment bracket to the other side Secure the alignment bracket using the second M8 screw Figure 11 Mounting the safety light curtain using the alignment...

Page 18: ...ews 10 Tighten the two lower screws Figure 14 Mounting the safety light curtain using the alignment brackets Steps 9 and 10 11 Turn the safety light curtains so that they face one another and so that...

Page 19: ...ackets Steps 11 and 12 12 Tighten the locking screws on all alignment brackets with a torque of 28 to 28 5 Nm in order to secure the safety light curtain in this position MOUNTING 3 8022867 2019 03 04...

Page 20: ...ability DANGER Risk of ignition or explosion b If you have to remove the cover when working on the safety light curtain make sure that the joints and o ring are clean and undamaged before refitting th...

Page 21: ...ollows Rotate 45 Figure 16 Rotating with the alignment bracket Aligning the sender and receiver with one another How to align the sender and receiver using the alignment bracket b Pay attention to the...

Page 22: ...que of 28 to 28 5 Nm b Switch the power supply off and then on again b Check the alignment quality display as described in the underlying operating instructions to make sure that components are still...

Page 23: ...ired 6 1 Regular cleaning DANGER Risk of ignition or explosion Static discharge could cause explosions in hazardous atmospheres b Always use anti static cleaning agents to prevent static charge b Do n...

Page 24: ...T6 Ex tb IIIC T56 C Db IP6X Weight Depending on the protective field height see Table of weights page 24 1 If you are using the full protective field width check to see if the orange LED lights up cle...

Page 25: ...89 6 44 5 1 100 2 1 068 2 1 035 142 1 50 8 Figure 17 Dimensional drawing sender and receiver protective field height 600 mm TECHNICAL DATA 7 8022867 2019 03 04 SICK O P E R A T I N G I N S T R U C T...

Page 26: ...58 7 161 8 89 6 44 5 142 1 50 8 Figure 18 Dimensional drawing sender and receiver protective field height 900 mm 7 TECHNICAL DATA 26 O P E R A T I N G I N S T R U C T I O N S C4000 Fusion Ex 8022867 2...

Page 27: ...2 1 635 237 7 206 9 50 8 142 1 Figure 19 Dimensional drawing sender and receiver protective field height 1 200 mm TECHNICAL DATA 7 8022867 2019 03 04 SICK O P E R A T I N G I N S T R U C T I O N S C40...

Page 28: ...ht curtain Operating instructions on CD ROM CDS Configuration Diagnostic Software on CD ROM 8 2 Ordering information C4000 Fusion Ex Table 4 Ordering information C4000 Fusion Ex Protective field heigh...

Page 29: ...ounting bracket and risers 3 6 41 14 5 8 5 43 5 59 62 30 6 75 37 5 15 7 8 4 30 Figure 20 Dimensional drawing swivel mount bracket with riser 2074626 8 22 25 69 22 5 24 7 5 90 5 15 1 36 1 5 50 1 44 1 2...

Page 30: ...cable flying leads 2022548 DOL 0612G20M075KM0 female connector straight with 20 m cable flying leads 2022549 DOL 0612G30M075KM0 female connector straight with 30 m cable flying leads 2022550 DOL 0612...

Page 31: ...W 3 9 A voltage supply NEC Class 2 SELV PELV input 100 V 120 V 220 V 240 V AC PS95WE24V 7028790 9 3 Alignment aid The following accessories can only be used outside the explosion hazardous area Part...

Page 32: ...specifications stated in the EU declaration of conformity have been used as a basis for this Complete EU declaration of conformity for download You can call up the EU declaration of conformity and the...

Page 33: ...1 to 6 17 12 Mounting the safety light curtain using the alignment brackets Step 7 17 13 Mounting the safety light curtain using the alignment brackets Step 8 18 14 Mounting the safety light curtain...

Page 34: ...4000 Fusion Ex 28 5 Ordering information for connecting cable M26 12 pin 0 75 mm 2 30 6 Order information for cable ready to assemble 30 7 Ordering information for cable gland 30 8 Ordering informatio...

Page 35: ...LIST OF TABLES 12 8022867 2019 03 04 SICK O P E R A T I N G I N S T R U C T I O N S C4000 Fusion Ex 35 Subject to change without notice...

Page 36: ...exico Phone 52 472 748 9451 E Mail mario garcia sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E Mail sales sick co nz Norway Ph...

Reviews: