Technical specifications
10.4 Dimensional drawings
10.4.1
Standard system (not cascadable)
Fig. 29: Dimensional drawing
C 4000 sender, standard
system (not cascadable).
Receiver, mirror image (mm)
Protective
field height S
[mm]
Dimensions L1
[mm]
Dimensions L2
[mm]
Dimensions A
[mm]
300
381
427
224
450
532
578
374
600
682
728
524
750
833
879
674
900
984
1030
824
1050
1134
1180
974
1200
1283
1329
1124
1350
1435
1481
1274
1500
1586
1632
1424
1650
1736
1782
1574
1800
1887
1933
1724
DIN 43651 plug (M26×11 + FE)
40
48
20
14
10
L2
L1
36.2
56.3
S
22.4
6
10.5
2.2
1
3.5
Sliding nut groove
for side mounting
A
74
approx
. 1
40 (c
onn.
r
ang
e)
100
approx
. 100
(c
onnec
tor range)
75
Cable sockets M26×11 + FE
with crimp contacts
65
Tab. 20: Dimensions depend-
ing on protective field height,
standard system (not
cascadable)