O P E R AT I N G I N S T R U C T I O N S | Bulkscan®
8014829/ZV98/2018-05-07 | S I C K
Subject to change without notice
7 2
COMMISSIONING
Switch to the
System
tab.
Configure the contamination measurement
Strategy
.
Configure the
Response time
.
Configure the
Threshold
for the contamination warning and error. Enter the degree of
available view as a % for the thresholds.
8.5
Scan frequency
The scan frequency is the frequency with which the Bulkscan® determines and outputs
measured values at the interface.
Scan frequency
Cycle time
25 Hz
40.0 ms
50 Hz
20.0 ms
Tab. 19: Configurable scan frequencies for Bulkscan® LMS111
Scan frequency
Cycle time
35 Hz
28.6 ms
50 Hz
20.0 ms
75 Hz
13.3 ms
Tab. 20: Configurable scan frequencies for Bulkscan® LMS111
•
If you configure the output of the
Volume quota
or the
Mass quota
on a digital
output, then make sure that duration of the pause between pulses is longer than
the cycle time resulting from the scan frequency (see "4.13 Digital outputs“ on page
• The selection of the scan frequency affects the energy consumption of the sensor.
System
tab,
Scan frequency
group
Note