4 3
ELECTRICAL INSTALLATION
6.3.3
Wiring encoder inputs
Encoder
Bulkscan
ENC1
ENC2
GND ENC
A (0°)
B (90°)
GND Encoder
V
S
Encoder
Fig. 24: Wiring encoder inputs
The encoder requires its own power supply (V
S
encoder and GND encoder).
6.3.4
Input circuits IN1 and IN2
Fig. 25: Input circuits IN1 and IN2
6.3.5
Connecting the outputs to a PLC
+
24 V EXT
OUT1, OUT2
1
4
3
Bulkscan
SPS
2
_
Fig. 26: Connecting the outputs to a PLC (active LOW)
Note
IN1 or IN2
GND EXT
Bulkscan