CONFIGURABLE FUNCTIONS
Click on
Digital outputs
to open the
Digital outputs
tab (see "4.13 Digital outputs“
Select the assignment
Mass flow rate
for the required output.
Select the required
Logic
.
Define the
Lower limit
, the
Upper limit
, and the associated
Hysteresis
.
How to configure the signaling of the mass flow rate on an analog output:
Switch to the
Interfaces
tab.
Click on
BAM 100
to open the
BAM 100
tab (see "4.14 Analog module BAM100“ on
Select the assignment
Mass flow rate
for the required output.
Define the
4 mA point
and the
20 mA point
.
4.6
Measurement of the bulk density
The bulk density is the mass transported per unit volume.
The sensor calculates the bulk density from the measured contour, the configured mass
flow rate, and the measured volume flow rate.
Alternatively you can set the bulk density as a fixed value or an analog value. The sen
-
sor then uses this value instead of the measured value.
You can smooth the measured value with the aid of the averaging filter (see "4.11 Aver
How to configure the calculation of the bulk density:
Switch to the
Measurement
tab.
Configure the
Belt speed
(see "4.1 Setting the belt speed“ on page 16).
Configure the
Mass flow rate
as a
Fixed value
or
Analog value
.
Activate the
Bulk density
as a
Calculated value
.
Configure the
Flow averaging filter
, if required.
How to configure the signaling of the bulk density on a digital output:
Switch to the
Interfaces
tab.
Click on
Digital outputs
to open the
Digital outputs
tab (see "4.13 Digital outputs“
Select the assignment
Bulk density
for the required output.
Select the required
Logic
.
Define the
Lower limit
, the
Upper limit
, and the associated
Hysteresis
.
How to configure the signaling of the bulk density on an analog output:
Switch to the
Interfaces
tab.
Click on
BAM 100
to open the
BAM 100
tab (see "4.14 Analog module BAM100“ on
Select the assignment
Bulk density
for the required output.
Define the
4 mA point
and the
20 mA point
.
4.7
Measurement of the bulk height
The sensor determines the height of the bulk on the conveyor belt from the measured
contour. This function can be used to protect downstream machines from bulk which is
too tall.
Note