Commissioning
This chapter provides information on the electrical installation, configuration and com‐
missioning of the Absolute encoder AHS/AHM36 SAE J1939 und AHS/AHM36 SAE
J1939 Inox.
b
Please read this chapter before mounting, installing and commissioning the
device.
6.1
Electrical installation
CAUTION
Switch the voltage supply off!
The machine/system could unintentionally start up while you are connecting the devi‐
ces.
b
Ensure that the entire machine/system is disconnected during the electrical instal‐
lation.
For the electrical installation you will need male and female connectors (see product
information for the AHS/AHM36 SAE J1939 und AHS/AHM36 SAE J1939 Inox).
6.1.1
Connecting the AHS/AHM36 SAE J1939 and AHS/AHM36 SAE J1939 Inox
The M12 male connector of the AHS/AHM36 SAE J1939 and AHS/AHM36 SAE J1939
Inox is located at the rear of the device. It is designed to be rotatable. This allows it to
be used either angled upwards, to the left or to the right, or (as shown) axially to the
rear. The cable can also be aligned as required by the application.
With male con‐
nector
With cable
The connection of the AHS/AHM36 SAE J1939 and AHS/AHM36 SAE J1939 Inox is
either implemented as a male connector, M12, 5-pin or as a cable connection with
flying leads.
4
1
3
2
5
Figure 4: Male connector of the AHS/AHM36 SAE J1939 and AHS/AHM36 SAE J1939 Inox
VDC
GND/CAN
CAN high
CAN low
CAN shield
RD
BU
BK
PK
WH
Figure 5: Cable connection of the AHS/AHM36 SAE J1939 and AHS/AHM36 SAE J1939 Inox
COMMISSIONING
6
8027379/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | AHS/AHM36 SAE J1939
AHS/AHM36 SAE J1939 Inox