Chapter
3
Operating Instructions
AFS60/AFM60 EtherNet/IP
22
Product description
3.4.2
Assembly Object
The Assembly Object allows assembling of data attributes of other objects in one single
object. The AFS60/AFM60 EtherNet/IP supports only static assemblies of attributes. For
this reason the number of instances is fixed.
Instance
Service
Description
01h
Get_Attribute_All
Returns the values of all attributes
0Eh
Get_Attribute_Single Returns the values of one attribute
Number
Access
Description
Data type
Default value
1
Get
Object revision index
UINT
0002h
2
Get
Maximum number of
object instances in this
class
UINT
0067h
3
Get
Number of object
instances in this class
UINT
0007h
6
Get
Highest existing class
attribute ID
UINT
0007h
7
Get
Highest implemented
instance attribute
UINT
0067h
Class attributes 4 and 5 are not implemented.
The encoder supports only “Input” and “Listen Only” connections.
Number
Connection
Description
Bits
Bytes
1
Input
Position value
32
4
2
Input
Position value
Warning and alarm flags
32
8
5
3
Input
Position value
Velocity
32
32
8
4 … 5
–
–
–
–
101
Input
Error
Position value
32
32
8
102
Input
Error
Position value
Warning and alarm flags
32
32
8
9
103
Input
Error
Position value
Velocity
32
32
32
12
100
Configuration
“Input-only”
Configuration data
192/0
24/0
110
Configuration
“Listen-only”
Dummy instance for the
configuration data of a “Listen-
only” connection
0
0
Instance attributes 4 and 5 from the encoder profile 22h are not implemented.
Instance attributes 100 to 110 are vendor specific attributes.
Tab. 11: Class services of the
Assembly Object
Tab. 12: Class attributes of
the Assembly Object
Note
Tab. 13: Instance attributes
of the Assembly Object
Notes
© SICK AG• Germany • All rights reserved
8018909/1EH9/2021-12-16
Subject to change without notice