NOTE
If the value is not present in the device, a zero byte (0x00) is transmitted for each
character.
Input values
Rel. Adr.
Description
0
Displays the version number of the firmware of the application processor
of the device as a string in the format
V000.000.000
.
Type
•
12 ASCII characters
12
Reserved
Type
•
8 byte
10.3.21
Module 35:
Version uC2/i10w
Type
Input module, 10 words
Description
This module can be used to query the version number of the firmware of the communi‐
cation processor.
NOTE
If the value is not present in the device, a zero byte (0x00) is transmitted for each
character.
Input values
Rel. Adr.
Description
0
Displays the version number of the firmware of the communication pro‐
cessor as a string in the format
V000.000.000
.
Type
•
12 ASCII characters
12
Reserved
Type
•
8 byte
10.4
Preset – moving to initialization position
The
Preset
function enables the measured distance value to be automatically adjusted
to a reference value (preset) known to the system during commissioning, maintenance
or device replacement.
NOTE
When activating the preset, the output of measured values of the distance sensor will
be temporarily unavailable. We recommend carrying out the preset while the machine
is at a standstill or running at very low speeds. The maximum activation number is
typically around 10,000 cycles. The offset value calculated when activating the preset
is permanently saved in the device.
PROFIBUS INTERFACE
10
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
79
Subject to change without notice